Temperature range : 32 to 392F (0 to 200C)
EMF tolerance : +/- 2.2C or +/- .75%
Grade : Extension Grade NPX/NNX
Positive : Ni-cr-si
Negative : Ni-si-magnesium
other name : Nicrosil
Special Limits of Error : +/- 1.1C or 0.4%
Type N Thermocouple extension wire (Nickel-Chromium-silicon / Nickel-Silicon-Magnesium):
The thermocouple compensation cables can also be termed as instrumentation cables, since they are used for process temperature measurement. The construction is similar to pair instrumentation cable but the conductor material is different. Thermocouples are used in processes to sense temperature and is connected to the pyrometers for indication and control. The thermocouple and pyrometer are electrically conducted by thermocouple extension cables / thermocouple compensating cables. The conductors used for these thermocouple cables are required to have similar thermo-electric (emf) properties as that of the thermocouple used for sensing the temperature.
Our plant mainly manufacture type KX, NX, EX, JX, NC, TX, SC/RC, KCA, KCB compensating wire for thermocouple, and they are used in temperature measurement instruments and cables. Our thermocouple compensating products are all made abiding by GB/T 4990-2010 'Alloy wires of extension and compensating cables for thermocouples' (Chinese National Standard), and also IEC584-3 'Thermocouple part 3-compensating wire' (International standard).
Code | Wires component of the thermocouple | |
+Positive leg | -Negative leg | |
N | Ni-cr-si (NP) | Ni-si-magnesium (NN) |
K | Ni-Cr (KP) | Ni-Al(Si) (KN) |
E | Ni-Cr (EP) | Cu-Ni<constantan> (EN) |
J | Iron (JP) | Cu-Ni<constantan> (JN) |
T | Copper (TP) | Cu-Ni<constantan> (TN) |
ASTM | ANSI | IEC | DIN | BS | NF | JIS | GOST |
(American Society for Testing and Materials) E 230 | (American National Standard Institute) MC 96.1 | (European Standard by the International Electrotechnical Commission 584)-1/2/3 | (Deutsche Industrie Normen) EN 60584 -1/2 | (British Standards) 4937.1041, EN 60584 - 1/2 | (Norme Française) EN 60584 -1/2 - NFC 42323 - NFC 42324 | (Japanese Industrial Standards) C 1602 - C 1610 | (Unification of the Russian Specifications) 3044 |
Working Temperature Range
Diameter/mm | Long time Working temperature /ºC | Short period Working temperature /ºC |
0.3 | 700 | 800 |
0.5 | 800 | 900 |
0.8,1.0 | 900 | 1000 |
1.2,1.6 | 1000 | 1100 |
2.0,2.5 | 1100 | 1200 |
3.2 | 1200 | 1300 |
|
Size range
Wire: 0.12 to 8.0 mm.
Maximum continuous operating temperature: up to 2,300F (1,260C)
Short term use: 2,336F (1,280C)
Thermocouple grade wire, -454 to 2300F (-270 to 1,260C)
Extension wire, 32 to 392F (0 to 200C)
![]() |